A preliminary understanding of the "plateau voltage" of lithium batteries

​Introduction 

         Lithium batteries have become the preferred power supply solution in modern electronic devices and energy storage systems due to their high energy density, long service life, and relatively low self-discharge rate. The performance of lithium batteries can be evaluated in many ways, with the voltage plateau being a key indicator.

         This article explains the concept of the voltage plateau, the main factors affecting its stability and height, and the characteristics of the voltage plateau. In addition, the discharge rate is discussed, a parameter closely related to the voltage plateau. It also touches on the essentials of the discharge plateau of lithium batteries and explains the scientific principles of voltage performance when electrochemical reactions reach a dynamic equilibrium.

 

1. The Concept of the Voltage Plateau 

        A plateau in a battery essentially means that the battery's charge/discharge curve is flat. For example, the charge/discharge curve of a lithium-ion battery using lithium iron phosphate as the positive electrode material (active material of the positive electrode) and graphite as the negative electrode material exhibits a plateau region.

        The discharge process of a fully charged lithium battery normally consists of three phases: the initial voltage drop, the subsequent stable period (plateau period), and the final voltage drop. Of these three phases, the stable period is the longest. The longer it lasts, the higher the battery's discharge plateau, which is normally closely related to the battery manufacturing process.

 

2. Main Influencing Factors: 

         For ternary lithium batteries, interrupt the charging process under constant voltage conditions when the voltage reaches 4.2 V and the current is less than 0.01 C, then let it stand for 10 minutes. At any discharge current rate, the discharge time is an important indicator of battery quality when the battery is discharged to 3.7 V. However, do not blindly pursue a high plateau. Sometimes the voltage plateau is high, but the capacity is reduced, as the voltage plateau varies under different rate conditions.

         Battery manufacturing process: Different lithium battery manufacturers have different market positioning and technical process means, which leads to differences in the controlled discharge plateau and thus affects the quality of the battery.

         Battery materials: The properties of the positive electrode material directly affect the discharge plateau phenomenon. For example, the potential of solid solution materials such as lithium cobalt oxide hardly changes with the lithium ion concentration, while materials such as lithium iron phosphate, which form a two-phase structure through phase changes, exhibit a clear plateau region during charging and discharging.

         Charge and discharge rate: The discharge rate affects the voltage change during battery discharge. The higher the discharge rate, the lower the battery's discharge voltage plateau can be.  

3. Characteristics of the platform voltage 

         Stability: The platform voltage is the most stable part of the battery voltage curve. During charging, the battery voltage remains stable in the platform stage; during discharging, the battery voltage is also relatively stable in the platform stage.

         Typical value: Different types of lithium batteries (such as lithium cobalt oxide, lithium iron phosphate, nickel cobalt aluminum, etc.) have different typical platform voltages. For example, the charging platform voltage of lithium cobalt oxide batteries is normally about 4.2 V, while that of lithium iron phosphate batteries is about 3.2 V.

 

4. Discharge performance 

         The discharge rate (F) is a parameter that describes the charging and discharging speed of a battery. It is defined as the "N-hour charge (discharge) rate" and is normally used to indicate how long it takes for a battery to be fully charged or discharged. If the battery capacity is, for example, 2200 mAh and it is charged at a current of 0.1 C, then the charging current I = 2200 mAh × 0.1 C = 220 mA

 

5. The type of discharge platform for lithium batteries 

         The platform phenomenon of the discharge voltage of lithium batteries is essentially the voltage performance when the electrochemical reaction reaches a dynamic equilibrium. This equilibrium point is the difference between the standard potential and the polarization potential. The properties of the positive electrode material directly affect this phenomenon. For example, the potential of solid solution materials such as lithium cobalt oxide changes slightly with the lithium ion concentration. Although it looks like a platform, it is actually only approximate. The real platform is a material such as lithium iron phosphate, which forms a two-phase structure through phase change and not through solubility change. This property ensures that a clear platform area is displayed during charging and discharging.

 

In conclusion

      As an important indicator of the discharge characteristics of lithium batteries, the stability and height of the platform voltage are directly related to the performance and manufacturing process of the battery. Understanding the characteristics of the platform voltage and the concept of the discharge rate is of great importance for the design, use, and maintenance of lithium batteries. With the continuous development of battery technology, an in-depth study of these basic properties will help drive the development of more efficient and safer battery systems.